Buy Now! ACI A/RH2-CP-RO : Room Relative Humidity Sensor, 2% Accuracy, RH Outputs: 0-5, 0-10 VDC & 4-20mA (Default), 10K Ohm Thermistor (Type II), Room (R) Infinity Enclosure (Beige), Override, Made in USA.
ACI A/RH2-CP-RO : Room Relative Humidity Sensor, 2% Accuracy, RH Outputs: 0-5, 0-10 VDC & 4-20mA (Default), 10K Ohm Thermistor (Type II), Room (R) Infinity Enclosure (Beige), Override, Made in USA The ACI Relative Humidity with Thermistor Room Series utilizes a thermoset polymer capacitive sensing element with a factory fitted hydrophobic filter to improve its moisture resistance. The sensing elements multilayer construction also provides excellent resistance in applications where dust, dirt, oils and common environmental chemicals are found. The RH room sensors include on board DIP switches which allow the user to select the desired output signal and can be powered by AC or DC power sources. Single point field calibration can be performed by using the increment and decrement calibration DIP switches to adjust your curve up or down in +/- 0.5% increments with each toggle of the corresponding switches. These enhancements provide increased flexibility and outstanding long-term reliability without the need to replace the sensors in the field. Applications: Humidification Dehumidification Monitoring Indoor Space Humidity Clean Rooms Hospitals Process Control Laboratories Museums Schools Office Buildings Data Centers ESD (Anti-Static) Control Specifications RH Supply Voltage (Reverse Polarity Protected): 4-20 mA / 0-5 VDC /  0-10 VDC RH Output Signal: 2-wire: 4 - 20 mA (Factory Default) /3-wire: 0-5 or 0-10 VDC and 4 - 20 mA (Field Selectable) RH Measurement Range: 0-100% Operating RH Range: 0 to 95% RH, non-condensing RH Stability | Repeatability | Sensitivity: Less than 2% drift / 5 years | 0.5% RH | 0.1% RH Nominal Thermistor Resistive Output @ 77°F (25°C) (Lead Wire Colors) Non-Linear NTC RHx-CP Series (Type II): 10KΩ (White/Green)   Datasheets ACI RH Room Relative Humidity/Thermistor Data Sheet ACI RH Room Relative Humidity/Thermistor Installation Sheet  

product specifications Accuracy±2.00%Application Outdoor Air Humidity, Economizer Control, Psychrometric Calculations, Enthalpy, Dew Point, Wash Down

ACI A/RH2-CP-RO, Room Humidity/Temp

A/RH2-CP-O | ACI | Humidity Sensor, OSA, ±2.00%, Field Selectable Output, 10K Type II

ACI A/RH2-CP-RO, Room Humidity/Temp

Humidity Sensors Automation Components, Inc.

ACI A/RH2-CP-RO, Room Humidity/Temp

AUTOMATION COMPONENTS INC Products - Shop At Radwell

ACI A/RH2-CP-RO, Room Humidity/Temp

Buy Clean Room Temperature Indicator, Humidity Sensor

The ACI Relative Humidity Outside Air transmitter is designed for monitoring and controlling humidity levels in outdoor environments. This

ACI A/RH2-CP-RO, Room Humidity/Temp

ACI A/RH1-O : Outside Air Relative Humidity Sensor, 1% Accuracy, RH Outputs: 0-5, 0-10 VDC & 4-20mA (Default), Plastic Outdoor Enclosure (Euro), Made

ACI A/RH2-CP-RO, Room Humidity/Temp

Automation Components

ACI A/RH2-CP-RO, Room Humidity/Temp

ACI, A/RH2-CP-R2

ACI A/RH2-CP-RO, Room Humidity/Temp

Premium ACI HVAC Products – Blackhawk Supply – Page 16

ACI A/RH2-CP-RO, Room Humidity/Temp

Humidity Sensors Automation Components, Inc.

ACI A/RH2-CP-RO, Room Humidity/Temp

HVAC-Talk: Heating, Air & Refrigeration Discussion

ACI A/RH2-CP-RO, Room Humidity/Temp

ACI - Shop ACI Sensors, Transmitters, Thermostats, & More

The ACI Relative Humidity with Thermistor Room Series utilizes a thermoset polymer capacitive sensing element with a factory fitted hydrophobic

ACI A/RH2-CP-RO, Room Humidity/Temp

ACI A/RH2-CP-R2 : Room Relative Humidity Sensor, 2% Accuracy, RH Outputs: 0-5, 0-10 VDC & 4-20mA (Default), 10K Ohm Thermistor (Type II), Room (R2)