Buy Now! ACI A/RH2-CP-RO : Room Relative Humidity Sensor, 2% Accuracy, RH Outputs: 0-5, 0-10 VDC & 4-20mA (Default), 10K Ohm Thermistor (Type II), Room (R) Infinity Enclosure (Beige), Override, Made in USA.
ACI A/RH2-CP-RO : Room Relative Humidity Sensor, 2% Accuracy, RH Outputs: 0-5, 0-10 VDC & 4-20mA (Default), 10K Ohm Thermistor (Type II), Room (R) Infinity Enclosure (Beige), Override, Made in USA The ACI Relative Humidity with Thermistor Room Series utilizes a thermoset polymer capacitive sensing element with a factory fitted hydrophobic filter to improve its moisture resistance. The sensing elements multilayer construction also provides excellent resistance in applications where dust, dirt, oils and common environmental chemicals are found. The RH room sensors include on board DIP switches which allow the user to select the desired output signal and can be powered by AC or DC power sources. Single point field calibration can be performed by using the increment and decrement calibration DIP switches to adjust your curve up or down in +/- 0.5% increments with each toggle of the corresponding switches. These enhancements provide increased flexibility and outstanding long-term reliability without the need to replace the sensors in the field. Applications: Humidification Dehumidification Monitoring Indoor Space Humidity Clean Rooms Hospitals Process Control Laboratories Museums Schools Office Buildings Data Centers ESD (Anti-Static) Control Specifications RH Supply Voltage (Reverse Polarity Protected): 4-20 mA / 0-5 VDC / 0-10 VDC RH Output Signal: 2-wire: 4 - 20 mA (Factory Default) /3-wire: 0-5 or 0-10 VDC and 4 - 20 mA (Field Selectable) RH Measurement Range: 0-100% Operating RH Range: 0 to 95% RH, non-condensing RH Stability | Repeatability | Sensitivity: Less than 2% drift / 5 years | 0.5% RH | 0.1% RH Nominal Thermistor Resistive Output @ 77°F (25°C) (Lead Wire Colors) Non-Linear NTC RHx-CP Series (Type II): 10KΩ (White/Green) Datasheets ACI RH Room Relative Humidity/Thermistor Data Sheet ACI RH Room Relative Humidity/Thermistor Installation Sheet
product specifications Accuracy±2.00%Application Outdoor Air Humidity, Economizer Control, Psychrometric Calculations, Enthalpy, Dew Point, Wash Down
A/RH2-CP-O | ACI | Humidity Sensor, OSA, ±2.00%, Field Selectable Output, 10K Type II
Humidity Sensors Automation Components, Inc.
AUTOMATION COMPONENTS INC Products - Shop At Radwell
Buy Clean Room Temperature Indicator, Humidity Sensor
The ACI Relative Humidity Outside Air transmitter is designed for monitoring and controlling humidity levels in outdoor environments. This
ACI A/RH1-O : Outside Air Relative Humidity Sensor, 1% Accuracy, RH Outputs: 0-5, 0-10 VDC & 4-20mA (Default), Plastic Outdoor Enclosure (Euro), Made
Automation Components
ACI, A/RH2-CP-R2
Premium ACI HVAC Products – Blackhawk Supply – Page 16
Humidity Sensors Automation Components, Inc.
HVAC-Talk: Heating, Air & Refrigeration Discussion
ACI - Shop ACI Sensors, Transmitters, Thermostats, & More
The ACI Relative Humidity with Thermistor Room Series utilizes a thermoset polymer capacitive sensing element with a factory fitted hydrophobic
ACI A/RH2-CP-R2 : Room Relative Humidity Sensor, 2% Accuracy, RH Outputs: 0-5, 0-10 VDC & 4-20mA (Default), 10K Ohm Thermistor (Type II), Room (R2)